LE-34
HOLDING TYPE SOLENOID LOCKS
Catalogue View

Product No. | RoHS | Remarks | Code | Ask Price | 2D | 3D |
---|---|---|---|---|---|---|
LE-34-1 |
![]() |
50132 | ||||
LE-34-2 |
![]() |
50133 | ||||
LE-34-3 |
![]() |
50106 | ||||
LE-34-13 |
![]() |
50347 |
Features
- Applicable to small doors.
- Two operations, sucking and returning, are performed by impressing pulse voltage in positive or negative direction and no power is held in each position.
Specifications
- Rated voltage: DC24V ±5°C
- Duty cycle: 10% (intermittent rating)
- Maximum power flow: under 0.5 sec
- Resting period: 4.5 sec or more
(after a power flow of 0.5 sec.) - Input signal: Pulse signal (100-500 ms)
- Ambient temperature: -5°C to +40°C
(non-condensing) - Operating humidity range: 85%RH or less (non-dewing)
Specific Use
- Pass boxes and various cases
Remarks
- Even if solenoid energization is within the maximum energization time, repeated energization (70°C) may cause the solenoid to become hot. If there is a risk of it being touched, measures should be taken to prevent burns with consideration given to heat radiation.
- The latch stroke, the retraction force and the extension force are value in the horizontal installation.
- Don't do continuous control action.
- Remove the load on the latch when operating electrically.